Plan Review Notes
Plan Review Notes For Permit 23011421
Permit Number 23011421
Review Stop M
Sequence Number 1
Notes
Date Text
2023-02-14 05:56:201ST REVIEW FMC
 PERMIT: 23011421
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THIS SUBMITTAL APPEARS TO BE FOR 1 WALK IN COOLER.
 THE SUBMITTAL HAS INCLUDED A TURBO AIR REFRIGERATION
 SYSTEM INSTALLATION AND OPERATION MANUAL AND ALSO IN
 THE SUBMITTAL IS A KEEPRITE REFRIGERATION PRODUCT DATA
 AND SPECIFICATIONS MANUAL. PLEASE INDICATE WHICH SYSTEM
 IS TO BE USED FOR THIS WALK IN COOLER AND REMOVE THE
 SPECS ON THE ONE THAT IS NOT USED. FBC 107.3.5
  
 2) PLEASE PROVIDE A ROOF DRAWING INDICATING THE
 LOCATION OF THE CONDENSING UNIT FOR THIS WALK IN
 COOLER. FBC 107.3.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  