Date |
Text |
2023-02-02 09:19:12 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| APPROVAL FL25621.05-R2 REQUIRES MULTIPLE INSTALLATION |
| METHODS FOR STRUCTURES LOCATED IN EXPOSURE B, C, OR D |
| HAVE EITHER FLAT ROOF OR GABLE/HIP ROOF WITH MAX SLOPE |
| OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS WIND |
| SPEED 170 MPH. PLEASE INDICATE (HIGHLIGHT/CIRCLE) |
| METHODS USED FOR EACH ZONE ON PAGE #3 OF THE EVALUATION |
| REPORT. THIS PROJECT IS LOCATED IN AN EXPOSURE CATEGORY |
| D AREA. |
| 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-4; |
| EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H |
| < 20); ULTIMATE WIND SPEED (170), IS NOT CORRECT. THE |
| CORRECT EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. |
| PRODUCT APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE |
| CATEGORY D ENCLOSED AREAS WITHOUT USING INSULATION. |
| 3. SUBMITTED PRODUCT APPROVAL FL9777-R16 HAS BEEN |
| REVISED TO FL9777-R17. PLEASE PROVIDE A COMPLETE SET; |
| IT COVERS MULTIPLE PRODUCTS & LIMITS OF USE. SELECT |
| PRODUCT DESCRIPTION AND LIMITS OF USE. ALL APPLICABLE |
| DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON |
| THE PRODUCT APPROVAL DRAWINGS. |
| 4. SUBMITTED PRODUCT APPROVAL FL12328-R9 HAS BEEN |
| REVISED TO FL1228-R10. PLEASE PROVIDE A COMPLETE SET; |
| IT COVERS MULTIPLE PRODUCTS & LIMITS OF USE. SELECT |
| PRODUCT DESCRIPTION AND LIMITS OF USE. ALL APPLICABLE |
| DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON |
| THE PRODUCT APPROVAL DRAWINGS. |
| 5. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R22 |
| SELECTED PRODUCT TYPE; LASTOBOND PRO HT-S UNDERLAYMENT |
| IS APPROVED FOR USE AS JOINT STRIPS IN WOOD SHAKES OR |
| WOOD SHINGLES INSTALLATION ONLY. |
| 6. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING |
| CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), |
| MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW |
| POSITIVE DRAINAGE. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |