Plan Review Notes
Plan Review Notes For Permit 23011118
Permit Number 23011118
Review Stop P
Sequence Number 3
Notes
Date Text
2023-04-17 10:13:263RD PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
  
 2. POOL HOUSE - 2020 FRC P3108.2.1 - THE SHOWER AND
 WATER CLOSET ARE BOTH UPSTREAM OF THE LAVATORY
 CONNECTION. ONLY ONE TRAPPED FIXTURE IS ALLOWED TO BE
 UPSTREAM OF THE VENTED FIXTURE'S CONNECTION TO THE
 HORIZONTAL BRANCH DRAIN BEING WET VENTED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  