2023-02-02 13:30:31 | POOL HOUSE |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| AMENDMENT |
| |
| CORRECTIONS NEEDED - |
| |
| 1) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT) |
| FBC 1803.2 |
| |
| 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| PRODUCT APPROVALS FOR THE EXTERIOR SLIDING GLASS DOOR, |
| EXTERIOR SWING DOOR AND THE ROOFING SYSTEMS - ALL |
| PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB |
| 107.3.4 |
| |
| 3) PLEASE SHOW THE ROOF SHEATHING TYPE AND THICKNESS - |
| FBC WPB 107.2.1 |
| |
| 4) DRAWING A-1.01 TYPICAL WALL SECTION SHOWS ATTIC |
| VENTILATION AND SPRAY FOAM INSULATION - SHOULD NOT HAVE |
| ATTIC VENTILATION WITH FOAM ATTACHED TO THE UNDERSIDE |
| OF THE ROOF SHEATHING. SEE FOAM INSULATION INSTRUCTIONS |
| AND PROVIDE THOSE INSTRUCTIONS. (ICC - ES EVALUATION |
| REPORT) - FBC R316.3 SURFACE BURNING CHARACTERISTICS. |
| UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM |
| PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN |
| MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION |
| SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND |
| SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450 |
| WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY |
| INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723. |
| |
| 5) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE |
| BUILDING AND AWAY FROM THE ADJACENT PROPERTY - FBC WPB |
| 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED |
| WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY |
| A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF |
| NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, |
| DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES |
| AND THE PROPOSED FINISHED GRADES, DEPICTING THE |
| PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD |
| AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT |
| SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT |
| SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES) |