Plan Review Notes For Permit 23011039 |
Permit Number |
23011039 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2023-03-21 13:22:49 | 09/14/23 REVISED TYPO ERRORS FOR CLARIFICATION. JG. | | | | BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #23011039 | | 6821 NORTON AVE | | | | 1- FLORIDA PRODUCT APPROVAL FL16546-R13 SUBMITTED IS | | FOR DOORS UP TO 9'-2" WIDE. NEED PRODUCT APPROVAL FOR | | 10.2 X 8 OVERHEAD GARAGE DOOR. | | FAC. 61G20.3001. | | | | 2- ) PROVIDE COMPLETE DESIGN CRITERIA INCLUDING THE | | CURRENT BUILDING CODE, ULTIMATE DESIGN WIND SPEED AND | | NOMINAL DESIGN WIND SPEED, WIND EXPOSURE, RISK CATEGORY | | AND DESIGN WIND PRESSURES FOR DOORS.. CLEARLY SPECIFY | | LOCATION OF DOORS (END OR INTERIOR ZONE) AND BUILDING | | MEAN ROOF HEIGHT. SEC. 1603.1.4 FBC-BUILDING. SEC. | | 107.3.5 CITY AMENDMENTS. | | | | PROVIDE THE DESIGN PRESSURES FOR EACH DOOR. AND, | | CLEARLY SPECIFY IF DORO LOCATED IN END OR INTERIOR | | ZONE. ALSO, SPECIFY BUILDING MEAN ROOF HEIGHT. BUILDNG | | HERIGHT ANDSEC. 1609.1 FBC-BUILDING. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|