Date |
Text |
2023-02-22 10:53:13 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 |
| COVERS MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; |
| ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, |
| ALLOWABLE SUBSTRATES, ATTACHMENT LIMITATIONS & |
| INSTALLATION APPROVED ASSEMBLIES. SELECT ATTACHMENT |
| LIMITATION SYSTEM USED FROM 5.8.3.1 DIRECT-TO-DECK |
| TABLE 4A: ALLOWABLE DESIGN PRESSURES, DIRECT-TO-DECK |
| UNDERLAYMENT IN TILE ROOF APPLICATIONS PAGE #6 & 7 OR |
| ATTACHMENT LIMITATION SYSTEM FROM 5.8.3.2 |
| MECHANICALLY-ATTACHED BASE SHEET TABLE 4B ALLOWABLE |
| DESIGN PRESSURES, 2-PLY UNDERLAYMENT SYSTEMS IN TILE |
| ROOF APPLICATIONS PAGES #8-14. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |