Plan Review Notes
Plan Review Notes For Permit 23010162
Permit Number 23010162
Review Stop B
Sequence Number 1
Notes
Date Text
2023-02-06 09:00:24JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL2533-R28 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO
 INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN
 BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE
 BOTTOM OF THE COVER PAGE. PRINT PAGES 1-5 ONLY.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL2533-R28 COVERS MULTIPLE ROOF SYSTEMS FOR
 WOOD DECKS; SYSTEM TYPE A1-F NO. W-1 THRU W-105.
 SELECTED SYSTEM TYPE TO BE USED. PROVIDE SYSTEM THAT
 MEETS OR EXCEEDS ZONE 3 DESIGN PRESSURE REQUIREMENTS
 FOR EXPOSURE CATEGORY D AREAS OF -131.42/PROVIDE SIGNED
 AND SEALED ENGINEERED NAILING CALCULATIONS WITH AN
 APPROVED SYSTEM.
 3. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL15216-R10
 HAS BEEN REVISED TO FL15216-R11. PLEASE PROVIDE A
 COMPLETE SET. FLORIDA PRODUCT APPROVAL FL15216-R11
 COVERS MULTIPLE INSTALLATION METHODS. INDICATE
 INSTALLATION METHOD ON SECTION 6.3 PAGE #4. PLEASE
 NOTE: LAST LINE OF PARAGRAPH 6.3.1.1; FBC REQUIREMENTS
 TAKES PRECEDENCE OVER MANUFACTUER???S INSTALLATION
 INSTRUCTIONS.
 4. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL10674-R17 COVERS MULTIPLE PRODUCTS &
 INSTALLATION METHODS. SELECT PRODUCT & INSTALLATION
 METHOD TO BE USED. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS.
 5. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  