Plan Review Notes For Permit 23010098 |
Permit Number |
23010098 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2023-02-17 07:12:50 | 2ND REVIEW FBC-2020 RES. PLUMBING | | PERMIT- 23010098 | | 2/17/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. PLEASE RESPOND TO THE 1ST | | REVIEW COMMENT COPIED BELOW. TO HELP EXPEDITE THE | | REVIEW PROCESS PLEASE SUBMIT A NARRATIVE RESPONSE AS | | NOTED BELOW. | | | | 1) SHEET P-1.1: THE PROPERTY IS LOCATED IN AN AE FLOOD | | HAZARD ZONE. THE EXTERIOR SHOWER DRAIN IS NOT APPROVED | | BASED ON SEC. R322.1.7 FBC RES- NEW AND REPLACEMENT | | SANITARY SEWAGE SYSTEMS SHALL BE DESIGNED TO MINIMIZE | | OR ELIMINATE INFILTRATION OF FLOODWATERS INTO SYSTEMS | | AND DISCHARGES FROM SYSTEMS INTO FLOODWATERS IN | | ACCORDANCE WITH THE PLUMBING PROVISIONS OF THIS CODE | | AND IN ACCORDANCE WITH CHAPTER 64E-6, FLORIDA | | ADMINISTRATIVE CODE, STANDARDS FOR ONSITE SEWAGE | | TREATMENT AND DISPOSAL SYSTEMS. | | A) PLEASE NOTE THAT SEC. 90-126 (5) WPB CODE OF | | ORDINANCES ALSO PROHIBITS STORM OR GROUND WATER TO | | DISCHARGE INTO THE SANITARY SEWER SYSTEM. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|