Date |
Text |
2023-01-06 10:25:35 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 COVERS |
| MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1) |
| THROUGH E(4). SELECT PRODUCT & SYSTEM TO BE USED. ALL |
| APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. |
| 2. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO. |
| 21-0209.07 POLYGLASS POLYSTICK XFR IS NOT APPROVED FOR |
| USE IN AN ADHESIVE SET TILE INSTALLATION; ITS APPROVED |
| FOR MECHANICAL TILE INSTALLATION. PLEASE MAKE THE |
| APPROPRIATE CORRECTIONS. |
| 3. FBC B 107.2.1 SUBMITTED MIAMI-DADE COUNTY NOA |
| 22-0614.08 PRODUCT POLYSET RTA-1 IS NOT APPROVED FOR |
| USE WITH MIAMI-DADE COUNTY NOA 22-0714.18 BARCELONA 900 |
| CONCRETE ROOF TILES. SELECT A PRODUCT THAT IS APPROVED |
| FOR USE FROM TABLE 5/TABLE 6 PAGE #6 OF MIAMI-DADE |
| COUNTY NOA 22-0714.18. |
| 4. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 |
| CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED |
| HIP & RIDGE METAL TO BE USED. (FL5374-R6) |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |