2023-02-03 15:10:05RE LOCATING A SFR - NEW FOUNDATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING S-1 - SECTION 1/S-1 - PLEASE SHOW THE
 BUILDING ANCHORAGE (HURRICANE STRAPS) TO THE NEW
 FOUNDATION - FBC R301.1
  
 2) DRAWING S-1 -SECTIONS 2 AND 3 LOOK TO BE IN THE
 WRONG PLACE ON THE PLAN - PLEASE CHECK CUT SECTION
 LOCATIONS.
  
 3) DRAWING S-4 - SECTIONS 6 AND 7 - LOCATIONS ARE NOT
 SHOWN ON THE PLAN.
  
 4) DRAWING S-1 - SECTIONS 4 AND 5 - LOCATIONS ARE NOT
 SHOWN ON THE PLAN.
  
 5) DRAWING A-4 - PLEASE SHOW THE STEP DIMENSION FROM
 THE FIRST FLOOR TO THE FRONT PORCH.
  
 6) PLEASE SHOW UNDER FLOOR VENTILATION LOCATIONS PER -
 FBC R408.1 VENTILATION.
 THE UNDER-FLOOR SPACE BETWEEN THE BOTTOM OF THE FLOOR
 JOISTS AND THE EARTH UNDER ANY BUILDING (EXCEPT SPACE
 OCCUPIED BY A BASEMENT) SHALL HAVE VENTILATION OPENINGS
 THROUGH FOUNDATION WALLS OR EXTERIOR WALLS. THE MINIMUM
 NET AREA OF VENTILATION OPENINGS SHALL BE NOT LESS THAN
 1 SQUARE FOOT (0.0929 M2) FOR EACH 150 SQUARE FEET (14
 M2) OF UNDER-FLOOR SPACE AREA, UNLESS THE GROUND
 SURFACE IS COVERED BY A CLASS 1 VAPOR RETARDER
 MATERIAL. WHERE A CLASS 1 VAPOR RETARDER MATERIAL IS
 USED, THE MINIMUM NET AREA OF VENTILATION OPENINGS
 SHALL BE NOT LESS THAN 1 SQUARE FOOT (0.0929 M2) FOR
 EACH 1,500 SQUARE FEET (140 M2) OF UNDER-FLOOR SPACE
 AREA. ONE SUCH VENTILATING OPENING SHALL BE WITHIN 3
 FEET (914 MM) OF EACH CORNER OF THE BUILDING.
  
 7) SHOW THE ACCESS FOR THE CRAWL SPACE - FBC R408.4
 ACCESS.
 ACCESS SHALL BE PROVIDED TO ALL UNDER-FLOOR SPACES.
 ACCESS OPENINGS THROUGH THE FLOOR SHALL BE A MINIMUM OF
 18 INCHES BY 24 INCHES (457 MM BY 610 MM). OPENINGS
 THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16
 INCHES BY 24 INCHES (407 MM BY 610 MM). WHERE ANY
 PORTION OF THE THROUGH-WALL ACCESS IS BELOW GRADE, AN
 AREAWAY NOT LESS THAN 16 INCHES BY 24 INCHES (407 MM BY
 610 MM) SHALL BE PROVIDED. THE BOTTOM OF THE AREAWAY
 SHALL BE BELOW THE THRESHOLD OF THE ACCESS OPENING.
 THROUGH WALL ACCESS OPENINGS SHALL NOT BE LOCATED UNDER
 A DOOR TO THE RESIDENCE.
  
 8) PLEASE PROVIDE A SOIL REPORT.
  
 9) PLEASE SHOW THE STORM WATER DRAINAGE FLOW AWAY FROM
 THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE
 SITE PLAN - FBC WPB107.2.5 SITE PLAN. THE CONSTRUCTION
 DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT
 SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE
 THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED
 WATER RETAINING SWALES)
  
 10) PLEASE PROVIDE A SURVEY SHOWING THE LOCATION OF THE
 BUILDING, THE BASE FLOOD DELINEATION LINES AND THE FEMA
 BASE FLOOD ELEVATIONS.
  
 11) PLEASE SHOW THE GARAGE FLOOR ELEVATION - ELEVATIONS
 LOWER THAN 2 FEET ABOVE FEMA BASE FLOOD ELEVATION WILL
 REQUIRE FLOOD VENTS - FBC R322.2.2
  
 12) PLEASE SHOW THE FLOOR ELEVATION FOR THE
 LAUNDRY/RESTROOM IN THE GARAGE - MUST BE 2 FEET ABOVE
 FEMA BASE FLOOD ELEVATION FBC R322.2.1
  
 13) PLEASE SHOW THE GARAGE FLOOR TO SLOPE PER FBC
 R309.1
  
 14) R408.7 FLOOD RESISTANCE.
 FOR BUILDINGS LOCATED IN FLOOD HAZARD AREAS AS
 ESTABLISHED IN TABLE R301.2(1):
  
 1.WALLS ENCLOSING THE UNDER-FLOOR SPACE SHALL BE
 PROVIDED WITH FLOOD OPENINGS IN ACCORDANCE WITH SECTION
 R322.2.2.
  
 2.THE FINISHED GROUND LEVEL OF THE UNDER-FLOOR SPACE
 SHALL BE EQUAL TO OR HIGHER THAN THE OUTSIDE FINISHED
 GROUND LEVEL ON AT LEAST ONE SIDE.
  
 15) PLEASE SHOW THE REQUIRED TERMITE PROTECTION - FBC
 R318
  
 16) PLEASE PROVIDE A PROPOSED ELEVATION CERTIFICATE -
 FBC WPB 107.3.5
  
 17) PLEASE PROVIDE FLOOD VENT CERTIFICATION/EVALUATION
 AND PRODUCT APPROVALS.
  
 18) A SEPARATE PERMIT IS REQUIRED FOR - EXISTING
 BUILDING DEMO AND DRIVEWAY.