2023-02-28 11:46:43WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22110423
 ADD: 2617 N AUSTRALIAN AVE.
 CONT: MASTER CONTRACTORS
 TEL: 561-712-8898
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. DEC. 28TH/ 2022
 ACTION: DENIED
  
 1) COVERSHEET:
 1A) COMPLIED.
 1B) SEMI-COMPLIED. CHANGED TO EXPOSURE D BUT DID NOT
 CHANGE PRESSURES ROOF AND WALL COMPONENTS AND CLADDING
 ( AS PLAN STATEMENT WORST CASE ALL OPENINGS) WALL ZONE
 5 AND ROOF ZONES 1, 2, & 3.
  
 2) COMPLIED.
 3) SHEET A-1 CONSTRUCTION FLOOR PLAN. SHOWS NEW
 EXTERIOR DOOR OPENINGS AND DOORS.
 3A)SEMI-COMPLIED, MISSING THE PRODUCT APPROVAL FOR THE
 NEW OPENING EAST SIDE, DOOR SIDELIGHTS (WINDOWS &
 VERTICAL MULLION, BETWEEN WINDOW & DOOR JAMB NEW DOUBLE
 GLASS DOOR SYSTEM. )
 1ST ROUND OF COMMENTS. COMPONENTS & CLADDING. PLEASE
 SUBMIT THE COMPONENTS AND CLADDING PRODUCT APPROVALS.
 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS
 (B) DOOR SIDELIGHT WINDOWS
  
 3B) SEMI-COMPLIED, NEED WINDOW AND MULLION REPORTS. W.
 P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE 61G20
 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP DRAWING
 STAMP OF APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 3C) SEMI-COMPLIED. NEED WINDOW AND MULLION REPORTS.
 IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER???S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 3D)(1) SEMI-COMPLIED. PLEASE PROVIDE THE WIDTH OF THE
 EXISTING SIDEWALK. EXISTING ADA RAMP DOOR TO HOTEL
 STAFF ENTRANCE ONLY NEEDS TO SHOW COMPLIANCE WITH
 2020-ACCESSIBILITY CODE FIGURE 404.2.1 FIGURE
 ( E ).
  
 3D)(2) NEW COMMENT. EXISTING DOOR WEST SIDE OF BUILDING
 AT EXISTING ADA RAMP TO STAFF TRAINING ROOM IS MISSING
 THE REQUIRED MANEUVERING CLEARANCE LETCH SIDE OF DOOR.
 ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES. DOORS.
 MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL
 COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL
 EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED
 LATCH SIDE FOR SIDE CLEARANCE.
 FIGURE 404.2.1(A)
  
 1ST ROUND OF COMMENTS. THE FLOOR PLAN SHOWS FROM THE
 NEW LOBBY THERE IS A SERIES OF EXISTING STAIRS THAT
 EITHER DROP OR ARE RAISED TO THE HOTEL AERA. THE FLOOR
 PLAN DOES NOT SHOW COMPLIANCE WITH VERTICAL
 ACCESSIBILITY REQUIREMENTS. PLEASE REVIEW SECTION
 201.1.1 VERTICAL ACCESSIBILITY & SECTION 408 FOR LULA
 LIFT, LIMITED USE LIMITED APPLICATION.
  
 3E) COMPLIED. BREAKROOM DOOR.
  
 3F) COMPLIED. INFILL HOTEL & STAFF TRAINING ROOM.
  
 3G)(1) COMPLIED. THE NEW BREAK ROOM SINK AND CABINETS .
 3G)(2) COMPLIED. 606.2 CLEAR FLOOR SPACE
  
 3H) COMPLIED DOOR.
  
 3I) COMPLIED. THE LOBBY RECEPTION DESK.
  
 3J) COMPLIED. DRINKING FOUNTAIN. NO FEWER THAN TWO
 DRINKING FOUNTAINS.
  
 3K) 2ND REQUEST. DRINKING FOUNTAINS PROTRUDING OBJECTS
 307.2 PROTRUSION LIMITS 307.2. OBJECTS WITH LEADING
 EDGES MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES
 ABOVE THE FLOOR SHALL NOT PROTRUDE MORE THAN 4 INCHES
 HORIZONTALLY INTO THE CIRCULATION PATH.
  
 3L) COMPLIED. DRINKING FOUNTAIN 602.2 CLEAR FLOOR SPACE
  
 3M) COMPLIED. POUT OUTLETS/ DRINKING FOUNTAINS
  
  
  
 4)COMPLIED. SHEET A-3 BATHROOM ACCESSIBILITY DETAILS:
  
 5) CMPLIED.
  
 6) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER