Plan Review Notes For Permit 22110308 |
Permit Number |
22110308 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2022-12-20 20:52:50 | ***CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC EB 702.5, REVISE PLAN TO SHOW WHAT TYPE OF | | WINDOW IS BEING REPLACED, THE CLEAR OPENING HEIGHT OF | | THE EXISTING WINDOW OPENING. IT APPEARS THAT THE | | PROPOSED WINDOW MIGHT NOT FALL UNDER THIS EXCEPTION AND | | ALSO DOES NOT COMPLY WITH EMERGENCY ESCAPE OPENING | | REQUIREMENTS. NOTE THAT OPENINGS 8 AND 9 ARE 24" IN | | HEIGHT, SO THE EGRESS OPENING WOULD BE LESS THAN 12". | | | | | | |
|