Plan Review Notes
Plan Review Notes For Permit 22110291
Permit Number 22110291
Review Stop B
Sequence Number 2
Notes
Date Text
2023-02-09 12:12:05JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL33818-R2 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: COVER SHEET
 (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE
 VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT).
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL33818-R2 SYSTEM NO. LOK-W-8 MAXIMUM DESIGN
 PRESSURE -96.75 DO NOT MEET THE MINIMUM ZONE 3 DESIGN
 PRESSURE REQUIREMENT OF -128.4 FOR EXPOSURE CATEGORY C
 AREAS HAVING GABLE/HIP ROOF WITH ROOF SLOPE BETWEEN
 2:12 & 12:12 WITH A MEAN ROOF HEIGHT 20 FEET OR LESS
 WIND SPEED 170 MPH, ENCLOSED BUILDING AS PER APPENDIX C
 PAGE #3. PROVIDE SIGNED AND SEALED ENGINEERING FOR USE
 OR SELECT A SYSTEM THAT MEETS THE ABOVE CRITERIA.
 PROJECT LOCATED IN EXPOSURE C CATEGORY AREA.
 3. FBC B 107.2.1 PLEASE NOTE: PRODUCT APPROVAL
 FL5259-R37 (NON-HVHZ) TABLES 4A & 4B, ALLOWABLE DESIGN
 PRESSURE UNDERLAYMENT CHARTS ARE REQUIRED FOR USE IN
 ROOF TILE APPLICATIONS ONLY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  