Plan Review Notes For Permit 22101430 |
Permit Number |
22101430 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2023-03-10 10:39:58 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 22101425, 22101430 | | 3/10/23 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P202: SHOW THE NEW DRINKING FOUNTAIN DRAIN AND | | VENT PIPE RUNS ON THE PLANS AND PROVIDE A SANITARY | | RISER DRAWING- SECS. 107.2.1 & 107.3.5.1.3 WPB. | | | | 2) SHEET A204: THE REVISED SHEET SHOWS NEW ACCESSIBLE | | DRINKING FOUNTAINS ON THE EXTERIOR OF THE BUILDING THAT | | APPEAR TO BE PROTRUDING OBJECTS IN THE CIRCULATION | | PATH- SEE SEC. 307.2 FBC ACC. IT APPEARS THE FOUNTAINS | | WILL HAVE TO BE RELOCATED AND RECESSED IN A NICHE, OR | | GUARDS WILL HAVE TO BE INSTALLED AT THE CURRENT | | LOCATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|