2023-05-09 12:06:14 | FAILED |
| |
| 1) THE SUBMITTED COMMUNICATION FACILITY PLACEMENT |
| PERMIT - CITY RIGHTS-OF-WAY (22040938) MUST BE APPROVED |
| PRIOR TO THIS PERMIT BEING APPROVED. SOME OF THE |
| COMMENTS BELOW ARE INCLUDED ON THE PLACEMENT PERMIT |
| REVIEW AS WELL AS WITH THIS PERMIT. |
| |
| 2) REPEAT COMMENT: THE SURVEY SHOWS THE POWER POLE THAT |
| WILL SUPPLY THE UNDERGROUND POWER ON PRIVATE PROPERTY |
| AND REQUIRING A CROSSING OF THE PRIVATE PROPERTY TO |
| REACH THE HANDHOLE AT STA 0+00. IN ORDER FOR THE |
| UNDERGROUND ELECTRIC TO CROSS PRIVATE PROPERTY, IT MUST |
| BE LOCATED WITHIN A GENERAL UTILITY EASEMENT. THE |
| SURVEY DOES NOT SHOW AN EASEMENT AT THIS LOCATION. IF |
| THERE IS AN EASEMENT, IT MUST BE SHOWN ON THE SURVEY |
| AND THE UNDERGROUND ELECTRIC MUST CLEARLY BE SHOWN IN |
| THE EASEMENT. IF NO EASEMENT IS PRESENT, THE |
| UNDERGROUND ELECTRIC MUST COME FROM AN ALTERNATIVE |
| LOCATION. |
| |
| 3) REPEAT COMMENT: SHEET E201 DOES NOT SHOW A POLE THAT |
| MEETS THE CITY'S STEALTH REQUIREMENTS. THE ORIGINAL |
| SUBMITTAL SHOWED A COMPLIANT POLE DESIGN. SHEETS A201 |
| AND A502 SHOW A COMPLIANT POLE. ALL PLANS MUST SHOW |
| CITY COMPLIANT POLES. |
| |
| 4) THE POLE HEIGHT AND STYLE (SUBJECT TO THE CORRECTION |
| OF SHEET E201) MEET CITY REQUIREMENTS. THE POLE COLOR |
| AT THIS LOCATION IS CORRECTLY SHOWN AS RAL/RAYCAP 7042 |
| TRAFFIC GREY A. |
| |