Plan Review Notes For Permit 22101282 |
Permit Number |
22101282 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2023-06-16 11:13:49 | WINDOWS AND DOORS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | DRAWINGS SHOW THAT YOU ARE REMOVING AND BLOCKING UP THE | | BATHROOM WINDOW - IF THE BATHROOM HAS AN EXISTING VENT | | - PLEASE SHOW THE EXISTING VENT ON THE WINDOW | | REPLACEMENT FLOOR PLAN. | | | | 1) AN EXHAUST SYSTEM WILL BE REQUIRED FOR THE BATHROOM | | - FBC R303.3 BATHROOMS. | | BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR | | ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN | | WINDOWS OF NOT LESS THAN 3 SQUARE FEET (0.3 M2), | | ONE-HALF OF WHICH MUST BE OPENABLE. | | EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE | | ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM ARE | | PROVIDED. THE MINIMUM LOCAL EXHAUST RATES SHALL BE | | DETERMINED IN ACCORDANCE WITH SECTION M1507. EXHAUST | | AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE | | OUTDOORS. | | | | |
|