2022-11-16 19:18:24 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #22101219 |
| 3311 POINSETTIA AVE |
| |
| 1- POLYGLASS POLYSTICK UNDERLAYMENT (NOA 21-1217.02) |
| DOESN'T LIST THE TILE BOND ROOF TILE ADHESIVE (NOA |
| 21-1006.03) AS APPROVED ADHESIVE TO BE USED WITH THIS |
| UNDERLAYMENT. PROVIDE UNDERLAYMENT LISTING THE TILE |
| BOND ADHESIVE. |
| FAC 61G20.3.001 |
| |
| 2- HIP AND RIDGE INSTALLATION: PROVIDE COMPLETE DETAILS |
| AND SPECIFICATIONS FOR HIP AND RIDGE INSTALLATION AS |
| REQUIRED BY SEC. R905.3.7.1 FBC-RESIDENTIAL. SPECIFY |
| STRUCTURAL SUPPORT MATERIAL AND PROVIDE PRODUCT |
| APPROVAL AS REQUIRED. |
| NOTE: CLEARLY MARK ON PRODUCT APPROVAL ATTACHMENT |
| METHOD. |
| |
| 3- ROOF TILE NOA 22-0714.17 AND ROOF TILE ADHESIVE |
| SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE TO BE USED |
| AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS TO |
| VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC |
| R301.2.1 FBC-RESIDENTIAL. |
| |
| 4- RAS 117 CALCULATIONS NEED THE ORIGINAL SEAL AND |
| SIGNATURE OF THE ENGINEER AS REQUIRED BY CHAPTER 471 |
| FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR |
| PUBLIC RECORDS. |
| NOTE: SUBMIT CALCULATIONS ELECTRONICALLY WITH |
| ENGINEER'S VERIFIABLE DIGITAL SIGNATURE OR PROVIDE HARD |
| COPY WITH ORIGINAL SEAL/SIGNATURE. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |