2022-11-02 16:54:392ND REVIEW FBC-2020 RES.FUEL GAS
 PERMIT- 22101052
 11/2/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE NEW GAS ELEVATION DRAWING SHOWS A DIFFERENT
 INLET AND OUTLET PIPING CONFIGURATION COMPARED WITH THE
 RISER. PLEASE MATCH THE DRAWINGS AND NOTE THAT A
 MINIMUM 1-INCH MAIN GAS PIPE IS REQUIRED FROM THE METER
 TO THE FIRST TEE WHERE THE ??-INCH INDOOR AND OUTDOOR
 PIPING CONNECT- TABLE G2413.4(1) FBC RES.
  
 2) THE GAS DRYER SHALL NOT BE LOCATED IN THE BATHROOM
 UNLESS THE INSTALLATION COMPLIES WITH SEC. G2406.2(5)
 OR G2406.2(6) FBC RES:
  
 ITEM 5- THE APPLIANCE IS INSTALLED IN A ROOM OR SPACE
 THAT OPENS ONLY INTO A BEDROOM OR BATHROOM, AND SUCH
 ROOM OR SPACE IS USED FOR NO OTHER PURPOSE AND IS
 PROVIDED WITH A SOLID WEATHER-STRIPPED DOOR EQUIPPED
 WITH AN APPROVED SELF-CLOSING DEVICE. ALL COMBUSTION
 AIR SHALL BE TAKEN DIRECTLY FROM THE OUTDOORS IN
 ACCORDANCE WITH SECTION G2407.6
  
 ITEM 6- A CLOTHES DRYER IS INSTALLED IN A RESIDENTIAL
 BATHROOM OR TOILET ROOM HAVING A PERMANENT OPENING WITH
 AN AREA OF NOT LESS THAN 100 SQUARE INCHES THAT
 COMMUNICATES WITH A SPACE OUTSIDE OF A SLEEPING ROOM,
 BATHROOM, TOILET ROOM OR STORAGE CLOSET.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  