Plan Review Notes For Permit 22100849 |
Permit Number |
22100849 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2022-12-20 15:18:31 | BUILDING PROVISO: | | 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT | | IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON | | 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS | | EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD, | | NON-ABSORBENT SURFACE. | | 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A | | BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS | | AND CEILING PANELS IN SHOWER AREAS SHALL BE OF | | MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN | | ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. WATER | | RESISTANT GYPSUM (MR BOARD) SHALL NOT BE USED FOR | | SHOWER & TUB ENCLOSURES BUT CAN BE USED FOR BACKING | | BOARD FOR A BASE FOR TILE IN WATER CLOSET COMPARTMENT | | WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM | | C840 AND THE MANUFACTURE'S RECOMMENDATIONS. | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | |
|