Date |
Text |
2023-07-11 12:18:08 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 |
| CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED |
| FLAT ROOF SYSTEM TO BE USED. INCLUDE COVER PAGE, |
| EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR |
| SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS |
| MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL |
| DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY |
| COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC |
| ENGINEERING. SUBMITTED MIAMI-DADE NOA NO.: 21-0701.02 |
| IS NOT AN APPROVED FLAT ROOF SYSTEM. CITY OF WEST PALM |
| BEACH IS NOT LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS |
| 150. |
| 2. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT |
| COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL |
| AND CHAPTER 11 OF THE 2020 FBC-PLUMBING |
| 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE |
| IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO |
| WALL CONNECTIONS WILL BE IMPROVED. THIRD REQUEST. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |