Date |
Text |
2022-11-08 09:56:13 | NEW SFR |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| AMENDMENT |
| |
| CORRECTIONS NEEDED - |
| |
| 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE |
| INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE |
| PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND |
| ROOFING SYSTEM. ALL PRODUCT APPROVALS NEED TO BE |
| REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER |
| OF RECORD FBC 107.3.4 |
| |
| 2) ONE BATHROOM NEEDS A 29 INCH CLEAR OPENING - THE |
| BEDROOM DOOR AND THE BATHROOM ON THE FIRST FLOOR WILL |
| NEED A 29 INCH CLEAR OPENING SINCE THE BATHROOM IS IN |
| THE BEDROOM - CLEAR OPENINGS OF DOORWAYS WITH SWINGING |
| DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR |
| AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. FBC |
| R320.1.1 |
| ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES, |
| CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE |
| BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE |
| BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH |
| A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING. |
| HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE |
| LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF |
| NOT LESS THAN 29 INCHES (737 MM). |
| |
| 3) PLEASE SHOW THE DRAFT STOP LOCATION AND CONSTRUCTION |
| DETAILS - FBC R302.12 DRAFTSTOPPING. |
| IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE |
| BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A |
| FLOOR-CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED |
| SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED |
| 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING SHALL DIVIDE |
| THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. |
| |
| 4) PLEASE PROVIDE A SITE PLAN THAT SHOWS THE STORMWATER |
| LOT DRAINAGE - FBC WPB 107.2.5 SITE PLAN. THE |
| CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY |
| PROPOSED WATER RETAINING SWALES) |
| |
| 5) A SEPARATE PERMIT IS REQUIRED FOR THE EXISTING |
| BUILDING DEMO AND THE DETACHED GARAGE. |
| |