2022-11-07 10:52:24 | RESIDENTIAL (R2) SECOND BUILDING REVIEW COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #22091328 |
| 1801 S FLAGLER DR # 1704 |
| |
| 1- OK. |
| |
| ORIGINAL COMMENT: |
| 2- SPECIFY MULLION SIZE AND FASTENING TO VERIFY |
| COMPLIANCE WITH THE DESIGN PRESSURES. SEC. 1609.1 |
| FBC-BUILDING. CLEARLY MARK ON PRODUCT APPROVAL |
| SUBMITTED |
| NOTE: COORDINATE WITH ITEM #1 ABOVE. |
| |
| RESPONSE: |
| MULLION SIZE HIGHLIGHTED ON SHEET 3 OF 18 OF FLORIDA |
| PRODUCT APPROVAL FL34545 SUBMITTED SHOWS A 50-5/8" A |
| 1X3 MULLION WITH A SPAN OF 50-5/8". BASED ON THE WINDOW |
| OPENING SHOWN ON THE WINDOW/DOOR SCHEDULE SUBMITTED |
| THIS MULLION SPAN IS SHORT. THE DESIGN PRESSURE SHOWN |
| ON THE MULLION SPAN FOR A 63" MULLION SPAN DOESN'T MEET |
| THE DESIGN PRESSURE SHOWN ON THE WINDOW/DOOR SCHEDULE |
| SUBMITTED. REVISE MULLION SIZE AS REQUIRED TO MEET THE |
| CALCULATED DESIGN PRESSURES. |
| SEC. 1609.1 FBC-BUILDING. |
| |
| ORIGINAL COMMENT: |
| 3- SPECIFY SLIDING GLASS DOOR NUMBER OF PANELS/SIZE AND |
| SILL HEIGHT TO VERIFY COMPLIANCE WITH THE DESIGN |
| PRESSURES. SEC. 1609.1 FBC-BUILDING. CLEARLY MARK ON |
| PRODUCT APPROVAL SUBMITTED. |
| NOTE: COORDINATE WITH ITEM #1 ABOVE. |
| |
| RESPONSE: |
| SILL HEIGHT HIGHLIGHTED ON TABLE 2A OF SHEET 7 OF 22 OF |
| NOA 20-0429.09 SUBMITTED DOESN'T MEET THE DESIGN |
| PRESSURE SHOWN ON THE WINDOW/DOOR SCHEDULE SUBMITTED. |
| REVISE AS REQUIRED TO MEET THE CALCULATED DESIGN |
| PRESSURES. |
| SEC. 1609.1 FBC-BUILDING. |
| |
| 4-OK. |
| |
| NOTE: ITEM #5 BELOW TO BE VERIFIED IN FIELD. |
| 5- WINDOW OPENING CONTROL DEVICES: WINDOW OPENING |
| CONTROL DEVICES ARE REQUIRED WHEN THE WINDOW SILL IS AT |
| A HEIGHT LESS THAN 36 INCHES ABOVE THE FINISHED FLOOR. |
| WINDOW OPENING CONTROL DEVICES NEED TO COMPLY WITH ASTM |
| F2090. |
| CLEARLY SPECIFY IF THERE ARE ANY WINDOWS WHERE THE |
| WINDOW SILL IS LESS THAN 36" ABOVE THE FINISH FLOOR. |
| SEE SEC. 702.4 FBC-EXISTING BUILDING CODE. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |