Date |
Text |
2022-11-01 09:05:52 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| APPROVAL FL15218-R8 COVERS MULTIPLE DESIGN PRESSURE |
| RATINGS. PLEASE SELECT CORRECT PLYWOOD THICKNESS, |
| FASTENER, DESIGN PRESSURE, FASTENER SPACING FOR TOP |
| EDGE/BOTTOM EDGE/CENTER ROWS # OF ROWS & SPACING FROM |
| TABLE 2 PAGE #4 OF THE EVALUATION REPORT THAT MEET OR |
| EXCEED THE MINIMUM DESIGN PRESSURE REQUIREMENT FOR ALL |
| ZONES EXPOSURE CATEGORY C AREAS. (-115.5). ALL |
| APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS |
| AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT |
| APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. SECOND |
| REQUEST. NOTE: THIS COMMENT REFERENCE THE PROPOSED TAG |
| & STICK UNDERLAYENT TO BE USED. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |