Plan Review Notes
Plan Review Notes For Permit 22090167
Permit Number 22090167
Review Stop G
Sequence Number 1
Notes
Date Text
2022-09-13 16:47:221ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22090167
 9/13/22
  
 CODES IN EFFECT:
  
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: PEX-AL-PEX IS NOT AN APPROVED GAS PIPING
 PER SECS. G2414.1- G2414.11 FBC RES. PLEASE PROVIDE AN
 APPROVED PIPING TO REPLACE IT SUCH AS SCHEDULE 40
 METALLIC, COPPER, OR CSST.
  
 B) THE RISER APPEARS TO SHOW THE PEX-AL-PEX PIPING
 UNDER THE HOUSE SLAB. PLEASE NOTE THAT PEX MATERIAL IS
 PART POLYETHLENE (PLASTIC) AND PLASTIC PIPE IS
 PROHIBITED FOR INSTALLATION UNDER BUILDINGS- SEC.
 G2415.17.1 FBC RES.
  
 2) THE $2350.00 JOB VALUE APPEARS TO BE LOW FOR THE
 SCOPE OF WORK FOR THE PROJECT. PLEASE PROVIDE AN
 ITEMIZED COST BREAKDOWN FOR THE PROJECT THAT INCLUDES
 LABOR, MATERIALS, AND APPLIANCES- SE. 109.3 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy