2022-10-14 09:12:01 | 1ST BUILDING REVIEW |
| RESULTS: CORRECTIONS NEEDED |
| |
| CHRISTOPHER S. THROOP, CBO, BN, PX, CFM |
| PLANS EXAMINER II |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| NFPA 70 2017 EDITION NEC 2017 |
| |
| ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: |
| |
| NOTICE: PERMIT TYPE CHANGED TO RES-ADD. |
| |
| 1. VALUE: CITY OF WPB CHPT. 1 |
| 109.3 BUILDING PERMIT VALUATIONS. |
| INSUFFICIENT INFORMATION TO EVALUATE THE VALUE OF THIS |
| PROJECT. PLEASE PROVIDE THE FOLLOWING BUILDING DATA: |
| EXISTING LIVING AREA |
| NEW LIVING AREA |
| TOTAL LIVING AREA |
| EXISTING COVERED AREA |
| NEW COVERED AREA |
| TOTAL COVERED AREA |
| EXISTING GARAGE AREA |
| NEW GARAGE AREA |
| |
| 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 |
| IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| INCLUDED BOUNDARY LINE URVEY. |
| FBC R401.3 SITE DRAINAGE |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| DOES NOT CREATE A HAZARD. |
| LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM |
| FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 |
| INCHES WITHIN THE FIRST 10 FEET. |
| |
| 3. PRODUCT APPROVAL FOR THE OVERHEAD DOOR EXPIRED ON |
| 3/30/22. |
| PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA FOR |
| THE PROPOSED OVERHEAD DOOR. |
| FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, |
| EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. |
| NOTE: NOAS DO NOT HAVE COVER SHEETS. |
| FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| |
| 4. PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA |
| FOR THE PROPOSED HS, HR AND ENTRY DOOR. |
| FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, |
| EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. |
| NOTE: NOAS DO NOT HAVE COVER SHEETS. |
| FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| |
| 5. IDENTIFY ATTIC ACCESS ON FLOOR PLAN OR ROOF FRAMING |
| PLAN. |
| R807.1ATTIC ACCESS. |
| BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION |
| SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT |
| HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR GREATER |
| OVER AN AREA OF NOT LESS THAN 30 SQUARE FEET (2.8 M2). |
| |
| 6. 2.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE |
| CALCULATED DESIGN PRESSURES ON PLAN PAGE S-2. |
| TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING |
| SCHEDULE FOR WOOD STRUCTURAL PANELS. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| |
| |
| |
| |
| |
| |
| |