2022-10-25 14:40:34NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT # 22080961
 606 59TH ST.
  
 1-LOT DRAINAGE
 PROVIDE DRAINAGE PLAN SHOWING HOW THE SURFACE DRAINAGE
 IS KEPT WITHIN THE LOT AND NOT DIVERTED TO ADJACENT
 PROPERTIES. PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE
 WITH THE FOLLOWING SECTIONS: R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY
 AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 2- ENERGY CALCULATIONS:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. NEED CORRECT BUILDER'S NAME. NEED TO SPECIFY
 PERMIT OFFICE AND JURISDICTION NUMBER (THIS
 JURISDICTION IS 604700). SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 C)NUMBER OF BEDROOMS IS INCORRECT. REVISE AS REQUIRED.
 SECTION R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 D)SIZE OF HOT WATER HEATER DOESN'T MATCH PLANS. REVISE
 AS REQUIRED. SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 E)ENERGY CALCULATIONS ARE TAKEN THE CEILING FAN CREDIT.
 PLANS DON'T SHOW CEILING FANS FOR ALL REQUIRED ROOMS.
 REVISE AS REQUIRED OR ENGINEER OF RECORD TO REVISE
 PLANS SHOWING COMPLIANCE WITH THIS SECTION. SEC.
 R405.7.6 FBC-ENERGY CONSERVATION.
  
 F)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION UPDATED TO $265,636. OWES
 $4913.37.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  