Date |
Text |
2022-09-23 16:54:44 | 1) PER SEC 94-442 (C)2.A. ONE SHADE OR FLOWERING TREE |
| IS REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR |
| PORTION THEREOF AND ONE SHRUB IS REQUIRED FOR EACH 500 |
| SQ FT OF OPEN SPACE OR PORTION THEREOF. |
| OPEN SPACE IS DETERMINED BY SUBTRACTING THE BUILDING |
| FOOTPRINT FROM THE GROSS LOT SQ FOOTAGE (ALL |
| NON-BUILDING AREA). PLEASE PROVIDE OPEN SPACE |
| CALCULATIONS TO DETERMINE REQUIRED TREES AND SHRUBS FOR |
| LOT. |
| |
| 2) PER SEC 94-442(G) LANDSCAPE PLAN MUST SATISFY A |
| MINIMUM TOTAL OF 25 POINTS FROM THE DESIGN OPTIONS |
| CHART. PLEASE SHOW WHAT ITEMS FROM THE PROPOSED |
| LANDSCAPE PLAN ARE MET ON THE CHART. |
| |
| 3) PER SEC 94-445(4) SHADE/FLOWERING TREES MUST HAVE A |
| MINIMUM HEIGHT OF 12 FT. PALMS MUST HAVE A MINIMUM |
| HEIGHT OF 8 FT OF CLEAR WOOD AND THE MINIMUM SIZE FOR |
| SHRUBS IS 3 GALLONS. ALL MATERIAL MUST BE FLORIDA GRADE |
| 1 OR BETTER. PLEASE PROVIDE PLANTING SPECS OF PROPOSED |
| MATERIAL THAT COINCIDE WITH THESE REQUIREMENTS. |
| |
| 4)PLEASE SHOW IF MATERIAL PROPOSED IS FLORIDA NATIVE OR |
| DROUGHT TOLERANT. PER SEC 94-482 60 PERCENT OF PLANT |
| MATERIAL PROPOSED MUST BE FLORIDA NATIVE OR DROUGHT |
| TOLERANT ACCORDING TO THE MOST RECENT EDITION OF SOUTH |
| FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| FLORIDA LANDSCAPES. PLEASE PROVIDE TOTAL CALCULATIONS |
| OF NATIVE/DROUGHT TOLERANT MATERIAL PROPOSED |
| |
| 5) PLEASE SHOW PROPERTY LINE LIMITS AND EXCLUDE THE |
| RIGHT OF WAY/SWALE. PLEASE SHOW ANY AND ALL UTILITY |
| INFRASTRUCTURE AND EASEMENTS ON LANDSCAPE PLANS |
| INCLUDING OVERHEAD WIRES. |