Date |
Text |
2022-09-20 11:31:22 | PLAN REVIEW ROOFING |
| |
| 1ST ROOFING REVIEW |
| RESULTS: CORRECTIONS NEEDED |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| NFPA 70 2017 EDITION NEC 2017 |
| |
| ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: |
| |
| NOTICE: A ROOFING SUB-PERMIT IS REQUIRED. |
| PERMITS - 105.1 REQUIRED. |
| |
| 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER |
| BARRIER PER FBC R905.1.1. |
| UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL |
| CONFORM TO THE APPLICABLE STANDARDS??? AND SHALL BE |
| APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION |
| R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. |
| |
| R905.3.3UNDERLAYMENT. CONCRETE TILE. |
| REQUIRED UNDERLAYMENT SHALL COMPLY WITH THE |
| UNDERLAYMENT MANUFACTURER???S INSTALLATION INSTRUCTIONS |
| IN ACCORDANCE WITH THE FRSA/TRI FLORIDA HIGH WIND |
| CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL, SIXTH |
| EDITION WHERE THE VASD IS DETERMINED IN ACCORDANCE WITH |
| SECTION R301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118, |
| 119 OR 120. |
| |
| 2. DESIGNER SHALL SELECT THE INSTALLATION METHOD OF THE |
| ROOF TILE. IF ADHESIVE IS TO BE USED, PROVIDE THE |
| PRODUCT APPROVAL OF THE ADHESIVE. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |