Date |
Text |
2022-08-15 08:55:33 | 1ST REVIEW FBC-2020 RES. FUEL GAS |
| PERMIT- 22080072 |
| 8/15/2022 |
| |
| CODES IN EFFECT: |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW THE COMMENT |
| BELOW AND NOTE THAT GAS CAN BE UNDER A SEPARATE PERMIT |
| IF REQUESTED. |
| |
| 1) SHEET 3 POOL DATA INDICATES AN LP GAS SYSTEM HOWEVER |
| THE SURVEY SHOWS A GAS METER. PLEASE CLARIFY THE TYPE |
| OF GAS- SEC. 107.1.2 WPB. |
| |
| 2) INSTALLATION OF THE POOL HEATER WILL ADD SUBSTANTIAL |
| BTU LOAD TO THE EXISTING SYSTEM. REFER TO SECS. G2412.3 |
| & G2412.4 FBC RES AND PROVIDE A COMPLETE GAS RISER FOR |
| THE RESIDENCE THAT INCLUDES THE FOLLOWING INFORMATION: |
| A) DELIVERY PRESSURE AT THE METER. |
| B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. |
| C) TYPES AND SIZES OF PIPING SUPPLYING THE EXISTING |
| APPLIANCES AND THE NEW WATER HEATER. |
| D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| TO THE MOST REMOTE APPLIANCE OUTLET. |
| E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| F) LOCATIONS OF REGULATORS, SHUTOFF VALVES. |
| G) OUTLET PRESSURES AT REGULATORS. |
| H) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| I) PIPE SIZING TABLES |
| |
| 3) SHEET 1: SHOW THE LOCATION OF THE GAS POOL HEATER |
| WITH CLEARANCE DISTANCE MEASUREMENTS TO OPERABLE |
| WINDOWS AND DOORS, AND OTHER AIR INTAKES INTO THE |
| BUILDING- SEC. G2427.8 FBC RES. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |
2022-08-07 19:54:08 | SIGNATURE IS A COPY JLEAHY |