2023-01-19 10:48:39 | 3RD REVIEW FBC-2020 PLUMBING |
| PERMIT-22071309 |
| 1/18/2023 |
| |
| CODES IN EFFECT: |
| FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. FAILED COMMENT #4 FROM THE |
| 1ST REVIEW IS LISTED BELOW. THE REQUESTED RESPONSE |
| ADDRESSING THE COMMENT FROM THE ARCHITECT WAS NOT |
| PROVIDED. AS PREVIOUSLY NOTED THERE ARE NUMBEROUS |
| EXEMPTIONS LISTED UNDER THE FBC ACC SECTIONS CALLED OUT |
| BELOW THAT WILL ALLOW FOR NON-ADA COMPLIANCE FIXTURES |
| TO BE INSTALLED, AND FOR INSTALLATION OF GRAB BAR |
| REINFORCEMENTS ONLY, HOWEVER THE BATHROOM MUST BE |
| DESIGNED AND CONSTRUCTED TO BE ADAPTABLE WHICH REQUIRES |
| CLEAR FLOOR PSACES AT FIXTURES AS OUTLINED BELOW |
| |
| 4) SHEET 2: REFER TO SEC. 213.1 & 213.2 FBC ACC AND |
| PROVIDE AN ENLARGED DIMENSIONED DRAWING FOR THE NEW |
| TOILET ROOM SHOWING THE FOLLOWING COMPLIANCE DETAILS |
| PER THE FBC ACC: |
| |
| A) REQUIRED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS |
| FOR THE WATER CLOSET- SECTION 604.3. |
| B) REQUIRED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS |
| FOR THE LAVATORY- SECTION 606.2. |
| C) REQUIRED. TURNING SPACE DIAMETER- SECTION 304.3. |
| D) REQUIRED. CENTERLINE OF THE WATER CLOSET FROM THE |
| SIDE WALL- SECTION 604.2. |
| E) GRAB BAR REINFORCEMENTS REQUIRED. LOCATIONS, |
| LENGTHS, AND MOUNTING HEIGHTS OF GRAB BARS FOR THE |
| WATER CLOSET- SECTION 604.5 & 609.4, FIGURES 604. |
| |
| ADVISORY: THE DESIGNER OF RECORD SHOULD REVIEW THE |
| FOLLOWING SECTIONS OF THE FBC ACC FOR FURTHER |
| COMPLIANCE INFORMATION AND EXCEPTIONS- SECS. |
| 201.1-201.1.1, 202.3- 202.4.2 & 203.1- 203.15 |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |