2022-08-05 10:48:5508/05/22 FAILED
  
 ALL PARKING AREAS NEED TO BE SETBACK AT LEAST 3 FT FROM
 THE SIDE PROPERTY LINE AND 5 FT FROM THE FRONT PROPERTY
 LINE. THIS ISNT SHOWN ON THE EAST OR SOUTH PROPERTY
 LINES
  
 ADDITIONALLY, CITY CODE STATES THAT THE LESSER OF 75%
 OR 1000 SQ FEET OF THE FRONT YARD MUST BE LANDSCAPED
 WITH LIVING PLANT MATERIAL. HOWEVER, IF YOU ARE
 INTENDING TO USE A PERMEABLE PAVER SYSTEM, 60 PERCENT
 OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH LIVING
 PLANT MATERIAL. THE FRONT YARD IS MEASURED FROM THE
 FRONT OF THE BUILDING TO THE PROPERTY LINE, AND THE
 SURVEY SHOWS NEARLY THE ENTIRE FRONT YARD IS GOING TO
 BE PAVED. UPON RESUBMITAL, SHOW THE TOTAL SQ FOOTAGE OF
 THE PROPOSED DRIVEWAY SO I CAN MAKE THIS CALCULATION.
  