Date |
Text |
2022-10-31 14:19:48 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 22071147 |
| ADD: 250 S AUSTRALIAN BLVD # 11TH FLOOR COMMON CORRIDOR |
| & RESTROOMS |
| CONT: TBD/ TO BE DETERMINED |
| TEL: |
| E-MAIL: [email protected] |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MON. OCT. 31/ 2022 |
| ACTION: DENIED |
| 1) SHEET LS101 BUILDING DESCRIPTION LIST 18 STORIES, |
| TYPE I-A, FULLY FIRE SPRINKLERED, FIRE ALARM TO BE |
| RETROFITTED. MISSING ELEVATOR LOBBIES AND OR |
| EXCEPTIONS. |
| 1A) ELEVATOR LOBBY REQUIRED. FBC-B 403.5.4 SMOKEPROOF |
| ENCLOSURES. |
| |
| 1B) EXISTING BUILDING CODE, LEVEL II ALTERATION. |
| 803.2.2 SUPPLEMENTAL SHAFT AND FLOOR OPENING ENCLOSURE |
| REQUIREMENTS. WHERE THE WORK AREA ON ANY FLOOR EXCEEDS |
| 50 PERCENT OF THAT FLOOR AREA, THE ENCLOSURE |
| REQUIREMENTS OF SECTION 803.2 SHALL APPLY TO VERTICAL |
| OPENINGS OTHER THAN STAIRWAYS THROUGHOUT THE FLOOR. |
| EXCEPTION: VERTICAL OPENINGS LOCATED IN TENANT SPACES |
| THAT ARE ENTIRELY OUTSIDE THE WORK AREA. |
| |
| 1C) FBC-B 1016.2 EGRESS THROUGH INTERVENING SPACES. |
| EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH |
| THIS SECTION. |
| 1.EXIT ACCESS THROUGH AN ENCLOSED ELEVATOR LOBBY IS |
| PERMITTED. ACCESS TO NOT LESS THAN ONE OF THE REQUIRED |
| EXITS SHALL BE PROVIDED WITHOUT TRAVEL THROUGH THE |
| ENCLOSED ELEVATOR LOBBIES REQUIRED BY SECTION 3006. |
| |
| 1D) FBC-B 403.5.4 SMOKEPROOF ENCLOSURES. EVERY REQUIRED |
| INTERIOR EXIT STAIRWAY SERVING FLOORS MORE THAN 75 FEET |
| (22 860 MM) ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT |
| VEHICLE ACCESS SHALL BE A SMOKEPROOF ENCLOSURE IN |
| ACCORDANCE WITH SECTIONS 909.20 AND 1023.11. |
| |
| 2) SHEET A101 THE CORRIDOR DOOR LEADING TO THE WOMENS |
| RESTROOM DOES NOT MEET THE 2020 ACCESSIBILITY CODE |
| SECTION CODE 404.2.4.1 SWINGING DOORS. SWINGING DOORS |
| AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING |
| WITH TABLE 404.2.4.1 & FIGURE.404.2.4.1 (A). THIS DOOR |
| IS AN EXISTING DOOR AND WOULD NEED TO COMPLY, UNDER |
| DISPROPORTION CAST RULE. |
| 202.4.1. DISPROPORTIONATE COST. ALTERATIONS MADE TO |
| PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED |
| AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL |
| ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE |
| ALTERATION( UP TO $51,697.00 DOLLARS) TO THE PRIMARY |
| FUNCTION AREA. COST THAT MAY BE COUNTED AS EXPENDITURES |
| REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL MAY |
| INCLUDE: (I) COST ASSOCIATED WITH PROVIDING AN |
| ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUT TO THE |
| ALTERED AREA; (II) COST ASSOCIATED WITH MAKING |
| RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COST |
| ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| TELEPHONE (TTY); (IV) COST ASSOCIATED WITH RELOCATING |
| AN ACCESSIBLE DRINKING FOUNTAIN. |
| |
| 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| |
| MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| PART-TIME/ SEMI-RETIRED. |
| |
| IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| BACK INTO THE OFFICE CALL |
| (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| THANK YOU. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |