Plan Review Notes
Plan Review Notes For Permit 22071045
Permit Number 22071045
Review Stop P
Sequence Number 1
Notes
Date Text
2022-08-01 08:53:481ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22071045
 8/1/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 2: PROVIDE THE PUMP CURVE ON THE SHEET MARKED
 UP TO SHOW THE TDH AND FLOW RATE OF THE SYSTEM- SECS.
 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 & R4501.7.2 & R4501.7.3
 FBC RES.
  
 2) SHEET 2: PLEASE NOTE AN RPZ BACKFLOW PREVENTER SHALL
 BE INSTALLED AT THE METER TO PROTECT THE POTABLE WATER
 SERVICE- SECS. C, D, & E WPB UTILITIES CROSS CONNECTION
 MANUAL. THE DEVICE SHALL BE INSTALLED UNDER A SEPARATE.
 A PVB BACKFLOW DEVICE IS ALSO REQUIRED FOR THE WATER
 SUPPLY PIPE TO THE AUTOFILL- SEC. P4501.9. FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  