Plan Review Notes
Plan Review Notes For Permit 22070679
Permit Number 22070679
Review Stop B
Sequence Number 1
Notes
Date Text
2022-08-09 07:27:40PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE STRUCTURAL ANALYSIS WAS DONE USING ASCE 7-10.
 THIS PROJECT IS UNDER THE 2020 FLORIDA BUILDING CODE
 WHICH REFERENCES ASCE 7-16. PROVIDE AN UPDATED
 STRUCTURAL ANALYSIS. FBC EXISTING BUILDING SECTION 406
  
 2) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE
 ENERGY FORM (R405-2020). FBC ENERGY CONSERVATION
 R405.2.1
  
 3) SHOW COMPLIANCE WITH FBC-R905.1.1.1 FOR ROOF
 UNDERLAYMENT WITH A SECONDARY WATER BARRIER. SPECIFY
 THE METHODE THAT WILL BE USED.
  
 4) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIALS
 THAT WILL BE USED OR REQUEST ON THE PLANS THAT THEY BE
 DEFERRED. FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR
 THOSE PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001
 PER FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 PROVIDE COMPLETE PRODUCT APPROVALS WITH FL OR NOA
 NUMBERS INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM
 DESIGN PRESSURES FOR EACH OF THE DIFFERENT ROOFING
 MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL MULLIONS
 AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE DEFERRED IF
 REQUESTED, HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND
 APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 5) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  