Plan Review Notes For Permit 22070634 |
Permit Number |
22070634 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2022-12-05 08:26:23 | BUILD OUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DRAWING S-3 -- FIG. 604.5.1 AND FIG. 604.7 SHOW THE | | INCORRECT GRAB BAR HEIGHT - - PLEASE SHOW THE TOILET | | GRAB BAR HEIGHTS - FBC 609.4 POSITION OF GRAB BARS. | | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, | | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | THE GRIPPING SURFACE | | | | 2) PLEASE SHOW THE SERVICE COUNTER HEIGHT AND CLEAR | | FLOOR SPACE TO COMPLY WITH FBC 904.4 SALES AND SERVICE | | COUNTERS. | | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH | | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE | | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR | | SERVICE COUNTER TOP. 904.4.1 PARALLEL APPROACH. | | A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915 | | MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM | | ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR | | OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED | | FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915 | | MM) MINIMUM LENGTH OF COUNTER. | | | | | | | | | | | | |
|