Date |
Text |
2022-08-18 16:25:24 | BUILD OUT |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| AMENDMENT |
| |
| CORRECTIONS NEEDED - |
| |
| 1) PLEASE SHOW THE ACCESSIBLE SEATING LOCATIONS - FBC A |
| 226.1 GENERAL. |
| WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION |
| OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING |
| SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL |
| COMPLY WITH 902. |
| |
| 2) DRAWING S-3 SHOWS CODE VERSION AS 2017 SHOULD BE |
| 2020 FBC ACCESSIBILITY |
| |
| 3) DRAWING S-3 - PLEASE USE THE WORDS "REFLECTIVE |
| SURFACE" WHEN REFERRING TO THE MIRROR DEMENSIONS FROM |
| THE FLOOR. FBC 603.3 MIRRORS. |
| MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR OR GROUND. |
| |
| 4) PLEASE SHOW THE TOILET GRAB BAR HEIGHTS - FBC 609.4 |
| POSITION OF GRAB BARS. |
| GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| THE GRIPPING SURFACE |
| |
| 5) DRAWING LS-1 AND S-1 - THE "OCCUPANCY NOTES, |
| OCCUPANCY CLASSIFICATION, OCCUPANT LOAD AND FLOOR |
| SQUARE FOOTAGE" DO NOT MATCH. |
| |
| 6) DRAWING S-1 AND LS-1 SHOW "DRAWING 1 OF 7" BUT THERE |
| ARE NOT 7 DRAWINGS. |
| |
| 7) PLEASE PROVIDE A DOOR SCHEDULE. |
| |
| 8) PLEASE SHOW THE SERVICE COUNTER HEIGHT AND CLEAR |
| FLOOR SPACE TO COMPLY WITH FBC 904.4SALES AND SERVICE |
| COUNTERS. |
| SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| SERVICE COUNTER TOP. |
| |
| 9) PLEASE SHOW THE PREVIOUS OCCUPANCY TYPE - FBC |
| CHAPTER 3 |
| |
| 10) ALL DRAWINGS NEED TO BE SIGNED AND SEALED BY THE |
| DESIGNER FBC WPB 107.1 |
| |
| 11) PLEASE SHOW RESTROOM WALL FINISHES TO COMPLY WITH |
| FBC 1210.2.2 WALLS AND PARTITIONS. |
| WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT |
| CONSIDERED A HARD SURFACE) |