Plan Review Notes
Plan Review Notes For Permit 22070634
Permit Number 22070634
Review Stop B
Sequence Number 1
Notes
Date Text
2022-08-18 16:25:24BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE ACCESSIBLE SEATING LOCATIONS - FBC A
 226.1 GENERAL.
 WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION
 OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING
 SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL
 COMPLY WITH 902.
  
 2) DRAWING S-3 SHOWS CODE VERSION AS 2017 SHOULD BE
 2020 FBC ACCESSIBILITY
  
 3) DRAWING S-3 - PLEASE USE THE WORDS "REFLECTIVE
 SURFACE" WHEN REFERRING TO THE MIRROR DEMENSIONS FROM
 THE FLOOR. FBC 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 4) PLEASE SHOW THE TOILET GRAB BAR HEIGHTS - FBC 609.4
 POSITION OF GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE
  
 5) DRAWING LS-1 AND S-1 - THE "OCCUPANCY NOTES,
 OCCUPANCY CLASSIFICATION, OCCUPANT LOAD AND FLOOR
 SQUARE FOOTAGE" DO NOT MATCH.
  
 6) DRAWING S-1 AND LS-1 SHOW "DRAWING 1 OF 7" BUT THERE
 ARE NOT 7 DRAWINGS.
  
 7) PLEASE PROVIDE A DOOR SCHEDULE.
  
 8) PLEASE SHOW THE SERVICE COUNTER HEIGHT AND CLEAR
 FLOOR SPACE TO COMPLY WITH FBC 904.4SALES AND SERVICE
 COUNTERS.
 SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH
 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE
 COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR
 SERVICE COUNTER TOP.
  
 9) PLEASE SHOW THE PREVIOUS OCCUPANCY TYPE - FBC
 CHAPTER 3
  
 10) ALL DRAWINGS NEED TO BE SIGNED AND SEALED BY THE
 DESIGNER FBC WPB 107.1
  
 11) PLEASE SHOW RESTROOM WALL FINISHES TO COMPLY WITH
 FBC 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)