2022-08-11 08:56:19 | PLAN REVIEW BUILDING |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II PX3169/SFP306 |
| BU1635 BN4338 |
| ASFPM CFM US-21-11935 |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| NFPA 70 2017 EDITION NEC 2017 |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| NOTICE: VALUE HAS BEEN ADJUSTED TO $18,127.00 PER THE |
| ICC BUILDING VALUATION DATA. |
| |
| SCOPE: SITE BUILT STORAGE STRUCTURE: |
| |
| PLEASE PROVIDE THE FOLLOWING DOCUMENTS: |
| |
| 1. PROVIDE A SITE PLAN.... |
| 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED |
| WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY |
| A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF |
| NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, |
| AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE |
| AND INCLUDED BOUNDARY LINE SURVEY. |
| NOTE: SURVEY SUBMITTED FOR REVIEW. FLOOD ZONE X. |
| |
| 2. PROVIDE THE FOLLOWING BUILDING PLANS |
| |
| 2A) PROVIDE A FOUNDATION PLAN FOOTINGS/SLAB ON |
| GRADE/REINFORCING/TIE DOWNS. |
| NOTE: APPLICATION STATES EXISTING SLAB. PROVIDE |
| DOCUMENTATION THAT THIS IS A STRUCTURAL SLAB WITH |
| THICKENED EDGE AND RE-INFORCING. |
| 2B) PROVIDE REQUIRED DIMENSIONS. |
| 2C) PROVIDE A FLOOR PLAN WITH FLOOR TO FOUNDATION |
| CONNECTION DETAIL, INCLUDE CONNECTOR TYPE AND |
| FASTENERS. |
| PROVIDE LOCATION OF WINDOW AND EXT. DOOR OPENINGS. |
| 2D) PROVIDE A WALL PLAN (SECTION VIEW) WITH WALL TO |
| FLOOR CONNECTION DETAIL, INCLUDE CONNECTOR TYPE AND |
| FASTENERS. |
| 2E) PROVIDE A ROOF FRAMING PLAN WITH ROOF TO WALL |
| CONNECTION DETAIL, INCLUDE CONNECTOR TYPE AND |
| FASTENERS. IDENTIFY LOCATION OF WINDOWS AND EXTERIOR |
| DOORS. |
| 2F) PROVIDE A WINDOW AND/OR DOOR SCHEDULE WITH ROUGH |
| OPENINGS AND DESIGN WIND LOADS. (COORDINATE SCHEDULE |
| WITH OPENINGS ON FLOOR PLAN). |
| OPTION: YOU MAY PLACE THE ROUGH OPENING AND DESIGN |
| PRESSURE NEXT TO THE OPENING ON THE FLOOR PLAN. |
| 2G) PROVIDE PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS, |
| DOORS, AND TIE DOWNS. >720 SQ. FT. SEE R301.2.1.2 |
| 2H) ELECTRICAL ? N/A |
| 2I) MECHANICAL ? N/A |
| 2J) PLUMBING ? N/A |
| 2K) ROOFING ? ROOFING SUB-PERMIT REQUIRED. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| |
| |