Date |
Text |
2022-12-09 08:04:52 | FLORIDA BUILDING CODE 2020 7TH EDITION |
| FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED |
| NFPA 70 2017 EDITION |
| |
| JAKE LEAHY |
| ELECTRICAL PLANS EXAMINER II |
| 561-805-6713 |
| [email protected] |
| |
| 1) UNLESS YOU CAN PROVIDE DOCUMENTATION FOR FLOOR BOXES |
| ON THE POOL DECK FLOOR, THAT THE OUTLETS WILL HAVE |
| COVERS THAT ARE WEATHER PROOF WITH CORDS PLUGED IN |
| PLEASE REMOVE ALL FLOOR OUTLETS IN THIS AREA. |
| 406.9(B)(1), 110.3(B) |
| |
| PLEASE INDICATE FOR ME WHAT TYPE OF DECKING IS TO BE |
| USED AROUND THE POOL, CONCRETE, WOOD, |
| COMPOSITE,ECT,ECT.) |
| |
| 2) FANS IN THE POOL AREA, PLEASE SHOW ON THE PLAN THE |
| HEIGHT AND DISTANCE FROM THE EDGE OF THE POOL TO THESE |
| FANS. 680.22(B)(4) |
| |
| 3) PAGE E104 SPEAKERS IN POOL OR ABOVE POOL? IF IN POOL |
| PLEASE PROVIDE A LISTING FOR THE SPEAKERS. 110.3(BB) |
| |
| 4) E-106 POOL EQUIPMENT CORROSIVE AREA? |
| |
| 680.14 CORROSIVE ENVIRONMENT. |
| (A) GENERAL. |
| AREAS WHERE POOL SANITATION CHEMICALS ARE STORED, AS |
| WELL AS AREAS WITH CIRCULATION PUMPS, AUTOMATIC |
| CHLORINATORS, FILTERS, OPEN AREAS UNDER DECKS ADJACENT |
| TO OR ABUTTING THE POOL STRUCTURE, AND SIMILAR |
| LOCATIONS SHALL BE CONSIDERED TO BE A CORROSIVE |
| ENVIRONMENT. THE AIR IN SUCH AREAS SHALL BE CONSIDERED |
| TO BE LADEN WITH ACID, CHLORINE, AND BROMINE VAPORS, OR |
| ANY COMBINATION OF ACID, CHLORINE, OR BROMINE VAPORS, |
| AND ANY LIQUIDS OR CONDENSATION IN THOSE AREAS SHALL BE |
| CONSIDERED TO BE LADEN WITH ACIDS, CHLORINE, AND |
| BROMINE VAPORS, OR ANY COMBINATION OF ACID, CHLORINE, |
| OR BROMINE VAPORS. |
| |
| (B) WIRING METHODS. |
| WIRING METHODS IN THE AREAS DESCRIBED IN 680.14(A) |
| SHALL BE LISTED AND IDENTIFIED FOR USE IN SUCH AREAS. |
| RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT, RIGID |
| POLYVINYL CHLORIDE CONDUIT, AND REINFORCED |
| THERMOSETTING RESIN CONDUIT SHALL BE CONSIDERED TO BE |
| RESISTANT TO THE CORROSIVE ENVIRONMENT SPECIFIED IN |
| 680.14(A). |