Plan Review Notes For Permit 22061092 |
Permit Number |
22061092 |
|
Review Stop |
B |
Sequence Number |
10 |
|
Notes |
Date |
Text |
2023-07-11 15:25:34 | REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DRAWING A-204 WAS REVISED AND THE NOTE FOR THE | | ACCESSIBLE POOL ENTRY WAS REMOVED - PLEASE SHOW THE | | ACCESSIBLE POOL ENTRY - FBC A 242.2 | | YOU CAN ADD "ACCESSIBLE POOL LIFT" TO THE DEFERRED | | SUBMITTALS LIST ON DRAWING CVR | | | | 2) NOA 20-1130.10 HAS BEEN SUBMITTED FOR THE ROLL UP | | DOOR (MARKED D8 ON THE DRAWING) - PLEASE SHOW HOW THIS | | DOOR IS SELF CLOSING PER FBC 716.5.9 DOOR CLOSING. FIRE | | DOORS SHALL BE LATCHING AND SELF- OR AUTOMATIC-CLOSING | | IN ACCORDANCE WITH THIS SECTION. | | | | | | | | | | | | | | |
|