2023-05-11 17:53:28NEW SINGLE FAMILY RESIDENCE(R3) FOURTH BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22060913
 922 AVON RD
  
 ORIGINAL COMMENT:
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORM IS PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 PREVIOUS COMMENT:
 RESPONSE: [ COMMENTS NOT ADDRESSED.]
 ENERGY CALCULATIONS SUBMITTED:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NOT ADDRESSED.
  
 B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING BUILDER'S NAME. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NOT ADDRESSED.
  
 C)CEILING INFORMATION ON ITEM #11 DOESN'T MATCH PLANS.
 PLANS SHOW VENTED ATTIC AND ROOF INSULATION.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NOT ADDRESSED.
  
 D) WINDOWS ORIENTATION AND AREA DON'T MATCH PLANS.
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NOT ADDRESSED.
  
 E)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NOT ADDRESSED.
  
 NEW COMMENT BASED ON REVISED PLANS:
 F)REVISE SPACES INFORMATION ON PAGE 2. NEW PLANS DON'T
 SHOW A KITCHEN ANYMORE.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 7- GUEST HOUSE ROOF FRAME DETAIL PLAN.
 ORIGINAL COMMENT:
 D)SPECIFY ROOF SHEATHING NAILING SPECIFICATIONS TO
 COMPLY WITH NEW 2020 FBC-RESIDENTIAL SPECIFICATIONS.
 SPECIFY THICKNESS, NAIL TYPE, SIZE AND SPACING. NOTE:
 NEED TO USE RING SHANK NAILS. ROOF SHEATHING NEEDS TO
 BE NAILED AT 4 INCHES O.C. IN THE FIELD AND EDGES AS
 REQUIRED BY SEC. R803.2.3.1 AND TABLE R803.2.3.1
 FBC-RESIDENTIAL.
  
 PREVIOUS COMMENT:
 RESPONSE: [ NOT RESOLVED.]
 ROOF SHEATHING SPECIFICATIONS SHOWN ON THE COMPONENT
 AND CLADDING PRESSURE ZONES ON SHEET S.3. DON'T COMPLY
 WITH TABLE R803.2.3.1 FBC-RESIDENTIAL. REVISE AS
 REQUIRED.
 NOTE: COORDINATE WITH ITEM 4(B) ABOVE.
  
 NEW RESPONSE ON 05/11/23:
 NEW DESIGNER OF RECORD. REVISE THE ROOF NAILING PATTERN
 SPECIFIED ON SHEET S-3 UNDER "MAX. COMPONENTS AND
 CLADDING DESIGN WIND PRESSURES". SPECIFICATIONS ARE
 INCOMPLETE. IT ONLY SPECIFIES THE SPACING AT THE EDGE.
 NEED TO PROVIDE ROOF SHEATHING NAILING SPECIFICATIONS
 FOR ALL ROOF ZONES. TABLE R803.2.3.1 FBC-RESIDENTIAL.
 NOTE: PLYWOOD ROOF SHEATHING NAILING IS REQUIRED ALL
 THE TIME. IT IS NOT CLEAR WHY ARCHITECT WROTE NOTE "IF
 REQUIRED". CLARIFY AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 ORIGINAL COMMENTS:
 16- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 PREVIOUS COMMENT:
 RESPONSE: [ NOT RESOLVED. THE C & C PRESSURES SPECIFIED
 ON SHEET S.1 FOR THE DOORS AND WINDOWS ARE QUITE HIGH
 FOR A BUILDING LESS THAN 15 FT IN HEIGHT. ]
 REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR IS NOT
 SPECIFYING IF SUBMITTING NOW OR LATER AS DEFERRED
 SUBMITTAL.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NOT ADDRESSED AND CONTRACTOR IS NOT
 SPECIFYING IF SUBMITTING NOW OR LATER AS DEFERRED
 SUBMITTAL.
 NOTE: PRODUCT APPROVAL NEEDS TO BE REVIEWED AND
 APPROVED IN WRITING (NOT SIGNING AND SEALING) BY
 DESIGNER OF RECORD AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 PREVIOUS COMMENT:
 B)SLIDING GLASS DOORS THAT MEET THE DESIGN PRESSURES
 CALCULATED BY THE ENGINEER OF RECORD ON REVISED S.1
 DRAWING.
  
 NEW RESPONSE ON 05/11/23:
 PRODUCT APPROVAL NEEDS TO BE REVIEWED AND APPROVED IN
 WRITING (NOT SIGNING AND SEALING) BY DESIGNER OF RECORD
 AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PREVIOUS COMMENT:
 C)SINGLE HUNG WINDOWS THAT MEET THE DESIGN PRESSURES
 CALCULATED BY THE ENGINEER OF RECORD ON REVISED S.1
 DRAWING.
  
 NEW RESPONSE ON 05/11/23:
 PRODUCT APPROVAL NEEDS TO BE REVIEWED AND APPROVED IN
 WRITING (NOT SIGNING AND SEALING) BY DESIGNER OF RECORD
 AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PREVIOUS COMMENT:
 D)ENTRY DOOR THAT MEET THE DESIGN PRESSURES CALCULATED
 BY THE ENGINEER OF RECORD ON REVISED S.1 DRAWING.
  
 NEW RESPONSE ON 05/11/23:
 REPEAT COMMENT. NO SUBMITTED AND PRODUCT APPROVAL NEEDS
 TO BE REVIEWED AND APPROVED IN WRITING (NOT SIGNING AND
 SEALING) BY DESIGNER OF RECORD AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 17- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
  
 NEW COMMENTS BASED ON REVISED DRAWINGS BY NEW DESIGNER
 OF RECORD:
 18- FLOOR PLAN LAYOUT WAS CHANGED BUT NEW ELECTRICAL,
 PLUMBING AND MECHANICAL PLANS WERE NOT SUBMITTED. NEED
 TO PROVIDE REVISED PLANS FOR ALL TRADES. SEC. 107.2.1
 CITY AMENDMENTS.
  
 19- REVISE THE ROOF DESIGN PRESSURES SPECIFIED ON SHEET
 S-3 UNDER "MAX. COMPONENTS AND CLADDING DESIGN WIND
 PRESSURES". SPECIFICATIONS ARE TOO LOW FOR BUILDING
 EXPOSURE "C".
 SEC. R301.2.1 FBC-RESIDENTIAL.
  
 20- REVISE VENTING SPECIFICATIONS ON THE TYPICAL WALL
 SECTION ON SHEET S-2.
 7"X24" VENTS AT 4'-0" O.C. DON'T ALLOW CROSS
 VENTILATION. THE ROOF IS FRAMED WITH 2X10'S AT 16"
 O.C.. REVISE AS REQUIRED BY SEC. R806.1 FBC-RESIDENTIAL
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  