2022-08-30 07:08:26 | PLAN REVIEW BUILDING |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II PX3169/SFP306 |
| BU1635 BN4338 |
| ASFPM CFM US-21-11935 |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| NFPA 70 2017 EDITION NEC 2017 |
| |
| 2ND REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| NOTICE: |
| PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. |
| PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN |
| PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER |
| PREVIOUS COMMENTS. |
| |
| |
| 1. |
| |
| 2. |
| |
| SHUTTERS |
| 3. PROVIDE A SCHEDULE OF OPENING PROTECTIVE DEVICES OR |
| ASSEMBLIES. |
| 1609.1.2 PROTECTION OF OPENINGS. |
| IN WIND-BORNE DEBRIS REGIONS, GLAZED OPENINGS IN |
| BUILDINGS SHALL BE IMPACT RESISTANT OR PROTECTED WITH |
| AN IMPACT-RESISTANT COVERING MEETING THE REQUIREMENTS |
| OF ANSI/DASMA 115 (FOR GARAGE DOORS AND ROLLING DOORS) |
| OR TAS 201, 202 AND 203, AAMA 506, ASTM E1996 AND ASTM |
| E1886 REFERENCED HEREIN, OR AN APPROVED |
| IMPACT-RESISTANT STANDARD AS FOLLOWS: |
| |
| WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE NOTE |
| FACTORS THAT APPLY DEPENDING ON SUBSTRATE, EDGE |
| DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON, |
| BE SPECIFIC AS TO WHICH TAPCON (TAPCON W/ADVANCED |
| THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). |
| |
| NOTICE: I HAVE UPLOADED A COPY OF THE CITY'S SHUTTER |
| SCHEDULE TO PROJECT DOX FOR YOUR REVIEW AND OR USE. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |