Plan Review Notes
Plan Review Notes For Permit 22060459
Permit Number 22060459
Review Stop B
Sequence Number 1
Notes
Date Text
2022-08-24 16:18:54BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 22060459
 REVIEWED: AUGUST 24, 2022
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1. 311.3 FBC[R] FLOORS AND LANDINGS AT EXTERIOR DOORS.
 THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH
 EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT
 LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
 DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED
 IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR
 LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2 PERCENT).
 - PROVIDE LANDING AT EXTERIOR SIDE OF DOORS IF GREATER
 THAN 2 RISERS PROVIDED.
  
 2. 408.1 FBC[R] VENTILATION. THE UNDER-FLOOR SPACE
 BETWEEN THE BOTTOM OF THE FLOOR JOISTS AND THE EARTH
 UNDER ANY BUILDING (EXCEPT SPACE OCCUPIED BY A
 BASEMENT) SHALL HAVE VENTILATION OPENINGS THROUGH
 FOUNDATION WALLS OR EXTERIOR WALLS.
 - PLEASE PROVIDE THE AMOUNT OF EXISTING UNDER FLOOR
 VENTILATION AND SHOW WHERE ACCESS PANEL IS LOCATED. IT
 APPEARS THAT THE ADDITION MAY BLOCK SOME OF THE OLD
 VENTS SO A NEW CALCULATION SHOULD BE DONE FOR THE
 EXISTING AND IF ANY NEW CRAWL SPACE IS BEING DONE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy