Plan Review Notes
Plan Review Notes For Permit 22060290
Permit Number 22060290
Review Stop B
Sequence Number 4
Notes
Date Text
2023-06-01 17:51:20NEW SINGLE FAMILY RESIDENCE(R3) FOURTH BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22060290
 1001 WINDSOR AVE
  
 PROVISO NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO ONCE
 CLEAR/LEGIBLE PLANS ARE UPLOADED TO PROJECTDOX. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY (EXCEPT FOR
 PRODUCT APPROVALS DEFERRED SUBMITTAL).
  
 ***IMPORTANT
 ****CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED
 AT THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION
 BEFORE PERMIT ISSUANCE.
  
  
 7- NEW ENERGY CALCULATIONS SUBMITTED:
 A)FORM 401-10 WAS SUBMITTED. NEED TO SUBMIT CURRENT
 405-2020 FORM.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)ITEM #5 ON PAGE 1 SPECIFIES WORST CASE SCENARIO.
 ENERGY CALCULATIONS NEED TO BE SITE SPECIFIC AS
 REQUIRED BY SEC. R405.4.2.1 (4) FBC- ENERGY
 CONSERVATION.
 REVISE AS REQUIRED.
  
 C)CONCRETE BLOCK INSULATION R-VALUE DOESN???T MATCH
 R-VALUE SPECIFIED ON TYPICAL WALL SECTION. REVISE AS
 REQUIRED TO MATCH.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D)REVISE SPACE INFORMATION ON PAGE 2. NUMBER OF
 OCCUPANTS CAN NOT BE 3.5. NEED TO ROUND UP THE NUMBER.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 E)REVISE DOOR ORIENTIN ON PAGE 3. ENTRY DOO IS ON THE
 EAST SIDE.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F)REVISE WINDOWS INFORMATION TO MATCH PLANS. REVISE
 WINDOWS ORIENTATION, WINDOWS FRAME TYPE (ALUMINUM, NOT
 VINYL), WINDOWS AREA AND WINDOWS OVERHANG DEPTH AND
 SEPARATION TO MATCH PLANS. ALSO, THERE IS NOT GLASS
 BLOCK ON PLANS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
  
 8- ALL RESUBMITTED PLANS ARE NOT LEGIBLE. NEED TO
 UPLOAD CLEAR AND LEGIBLE DRAWINGS. SEC. 107.2.1 CITY
 AMENDMENTS. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 RESPONSE:
 PLANS ARE STILL NOT LEGIBLE.
  
 9- ENGINEER TO REVISE SITE DRAINAGE PLAN ON SHEET 8.
 THE PROPOSED GRADE AT THE SWALE AREA IS HIGHER THAN THE
 ADJACENT GRADE. ALSO, IT DOESN'T MATCH SECTION DETAILS
 A-A, B-B AND C-C.
 ACCORDING TO SECTION DETAILS A-A, B-B AND C-C THE GRADE
 IS HIGHER AT THE PERIMETER OF THE LOT. ENGINEER OF
 RECORD TO PROVIDE DETAILS AND SPECIFICATIONS SHOWING
 HOW THE RAISED GRADE IS SUPPORTED. IF RETAINING WALLS
 ARE REQUIRED, THEN SEPARATE PERMIT IS REQUIRED. SEC.
 105.1 CITY AMENDMENTS, SEC. 105.2.5 CITY AMENDMENTS.
 SEC. R401.3 FC-RESIDENTIAL.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 RESPONSE:
 UNABLE TO READ THE PLANS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  