Date |
Text |
2022-07-12 10:14:47 | 1. PLEASE COORDINATE WITH THE BANYAN BOULEVARD PROJECT |
| FOR THE LOCATION OF THE LIGHT POLES. CONFIRM LOCATION |
| IS CONSISTENT. MOVE POLES TO PLANTING AREAS IF THAT IS |
| THE DESIGN LOCATION FOR THE BANYAN STREETSCAPE. |
| COORDINATE WITH VLADIMIR JEANNIOT (561)-494-1107 |
| 2. LIGHT POLES ALONG OLIVE AVENUE SHALL BE MOVED TOTHE |
| PLANTING AREA, ALIGN WITH THE TREE PLACEMNT. |
| 3.PLEASE PROVIDE PHOTOMETRICS FOR THE GROUND FLOOR TO |
| CONFIRM COMPLIANCE WITH REQUIRED 0.6 FOOTCANDLES ABOVE |
| ONE FOOT AT THE CURB. |
| 4. FURTHER DISCUSSION IS NEEDED FOR THE MATERIALS |
| PROPOSED ALONG THE SIDEWALK. PROJECT SHALL FIT IN THE |
| LARGER DESIGN OF BANYAN BOULEVARD AND OLIVE AVENUE. |
| 5. PLEASE CONFIRM THE PROPOSED LIGHTING FOR THE GARAGE |
| MEETS THE SITE PLAN APPROVAL CONDITION. PLEASE PROVIDE |
| DETAILS FOR THE PROPOSED FIXTURES. |
| 6. PROPOSED STRUCTURE OVER ALLEY REQUIRES A RIGHT OR |
| WAY AERIAL EASEMENT. PLEASE PROVIDE ADDITIONAL DETAILS. |
| MINIMUM CLEARANCE FOR FIRE DEPARTMENT AND UTLITIES IS |
| REQUIRED. PLEASE COORDINATE WITH BOTH DEPARTMENT AND |
| THE ENGINEERIGN DEPARTMENT. |
| 7. PLEASE PROVIDE MORE INFORMATION ABOUT THE MECHANICAL |
| SCREENING ON THE ROOF TOP. PROPOSED SCREENING IS 10" |
| ABOVE THE MAXIMUM 20' PERMITTED FOR MECHANICAL. IF THE |
| ELEMENT IS DESIGNED ABOVE A SIMPLE MECHANICAL AND |
| BECOMES AN ARCHITECTURAL FEATURE IT CAN BE A MAXIMUM |
| 30' ABOVE THE 152' MAXIMUM ALLOWED. |
| 8. ALL CONDITIONS OF APPROVAL FOR THE SITE PLAN, DAC |
| AND HISTORIC PRESERVATION BOARD ARE APPLICABLE. PLEASE |
| CONFIRM COMPLIANCE. |
| 9. PLEASE PROVIDE A RESPONSE LETTER WITH RESUBMITTAL. |
| FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| APONTE AT 561-822-1439. |