2022-06-14 16:19:01 | 1ST REVIEW FBC-2020 PLUMBING |
| PERMIT-22041540 |
| 6/14/2022 |
| |
| CODES IN EFFECT: |
| FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEETS A0.0 & P0.1: PROVIDE PLUMBING FIXTURE |
| CALCULATIONS IN COMPLIANCE WITH SEC. 810.1 FBC EX, AND |
| TABLE 403.1 FBC P. PROVIDE A SCHEDULE INDICATING THE |
| REQUIRED AND PROVIDED NUMBER OF FIXTURES. |
| |
| 2) P-1.1: THE 1/2-INCH HW SUPPLY PIPES ARE EXCEEDING |
| THE 0.5 FT. MAXIMUM ALLOWABLE LENGTHS TO THE LAVATORY |
| FAUCETS- TABLE C404.5.1 FBC EC. A RECIRCULATION PUMP |
| FOR THE HW SYSTEM OR POINT OF USE WATER HEATERS ARE |
| REQUIRED. |
| |
| 3) P-1.1: TEMPERED OR COLD WATER SHALL BE DELIVERED |
| FROM THE NEW LAVATORIES- SEC. 419.4 FBC P. PROVIDE ASSE |
| 1070 APPROVED MIXING VALVES- SEC. 607.1.2 FBC P. |
| |
| 4) P-1.1: A MEANS OF LIMITING THE HW DELIVERY |
| TEMPERATURES TO THE MOP SINK AND BREAK ROOM SINK IS |
| REQUIRED PER SEC. 607.1.1 FBC P. |
| |
| 5) P-1.1: THE MOP SINK FIXTURE DRAIN SHALL DISCHARGE |
| DOWNSTREAM OF THE BATHROOM HORIZONTAL WET VENT- SEC. |
| 912.1 FBC P. |
| |
| 6) P-1.1: PROVIDE A WATER HAMMER ARRESTOR AND BACKFLOW |
| PREVENTER FOR THE WATER SUPPLY LINE TO THE |
| REFRIGERATOR- SEC. 604.9 AND 608.3 FBC P. |
| |
| 7) A-3.0: PROVIDE CLEAR FLOOR SPACE DIAGRAMS AND |
| DIMENSIONS FOR THE ACCESSIBLE WATER CLOSETS AND |
| LAVATORIES- SECS. 604.3 & 606.2 FBC ACC. |
| |
| 8) A-3.0: THE SPECIFIED PAINTED GYPSUM WALL BOARD FOR |
| THE FIXTURE SURROUNDS IN THE BATHROOMS AND AT THE MOP |
| SINK IS NOT IN COMPLIANCE WITH SEC. 310.3 FBC P AND |
| SEC. 1210.2.2 FBC B- GYPSUM WALL BOARD IS NOT A HARD, |
| NONABSORBENT MATERIAL. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |