2022-05-14 11:00:47****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FS471 DOCUMENTS PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. THIS APPEARS TO BE A SCAN OF
 ENGINEERING THAT ORIGINALLY HAD A DIGITAL SIGNATURE.
 CONTACT THE ENGINEER TO OBTAIN A DIGITALLY SIGNED
 ORIGINAL AND UPLOAD WHEN RESUBMITTING.
  
  