Plan Review Notes
Plan Review Notes For Permit 22041185
Permit Number 22041185
Review Stop Z
Sequence Number 1
Notes
Date Text
2022-05-02 12:39:3405/02/22 FAILED -
  
 PER CITY CODE,
 EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE. A FENCE WAS NOT SHOWN ON THE POOL
 PLAN, IDEALLY A SURVEY WOULD BE PROVIDED SHOWING A
 FENCE AROUND THE PROPERTY.
  
 ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH A
 BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. THIS
 CAN BE ADDRESSED BY PROVIDING A SURVEY SHOWING THE
 FENCE IMPOVEMENT
  
 IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT TO OR
 SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN AWAY
 FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. THERE
 IS NO DRAINAGE PLAN OR DRAINAGE NOTES INCLUDED FOR THE
 PATIO SURROUNDING THE POOL
  
 ADDITIONALLY, MECHANANICAL EQUIPMENT (SUCH AS POOL
 EQUIPMENT) CANNOT PROTRUDE MORE THAN 4 FT INTO ANY
 REQUIRED SETBACK. PLEASE SPECIFY THIS MEASUREMENT ON
 THE POOL PLAN
  