Date |
Text |
2022-06-13 10:59:25 | PLAN REVIEW BUILDING |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II PX3169/SFP306 |
| BU1635 BN4338 |
| ASFPM CFM US-21-11935 |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| NFPA 70 2017 EDITION NEC 2017 |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| NOTICE: ADD FILL TO THIS PERMITS SCOPE OF WORK OR A |
| SEPERATE PERMIT FOR FILL WILL BE REQUIRED. |
| THE PERMIT APPLICATION AND PLANS NEED TO BE CLEAR THAT |
| FILL IS INCLUDED UNDER THIS PERMIT. |
| ADJUST VALUE ACCORDINGLY. |
| |
| 1. PROVIDE A SITE DRAINAGE PLAN WITH A CURRENT BOUNDARY |
| LINE SURVEY PER FBC R401.3 |
| IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| INCLUDED BOUNDARY LINE SURVEY. |
| FBC R401.3 SITE DRAINAGE |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| DOES NOT CREATE A HAZARD. |
| LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM |
| FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 |
| INCHES WITHIN THE FIRST 10 FEET. |
| |
| 2. PROVIDE AN ELEVATION PROFILE OF THE WALLS BETWEEN |
| THIS LOT AND LOT 10 AND THIS LOT AND LOT 12. INCLUDE |
| TOP OF WALL (TOW) AND TOP OF GRADE (TOG) ON BOTH SIDES |
| OF THE WALLS. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 3. WATERPROOFING OF INTERIOR SIDE OF WALL IS REQUIRED. |
| PROVIDE A CURRENT FLORIDA PRODUCT APPROVAL, UL DESIGN |
| OR PRODUCT SPECIFICATIONS. |
| R406.2CONCRETE AND MASONRY FOUNDATION WATERPROOFING. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| |
| |