Date |
Text |
2022-05-03 17:18:47 | CODES IN EFFECT: |
| FBC = FLORIDA BUILDING CODE 2020 7TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| 6TH ED, CHAPTER 1 |
| WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| MANUAL REVISED 2017 |
| FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 |
| 7TH EDITION |
| FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION |
| FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH |
| EDITION |
| FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION |
| FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION |
| NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES |
| FAC= FLORIDA ADMINISTRATIVE CODE |
| |
| 22041032 1641 WORTHINGTON RD # 120 |
| |
| PLUMBING COMMENTS: DENIED |
| |
| 1. PER FBC ACC 305.5CLEAR FLOOR OR GROUND SPACE SHALL |
| BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH |
| TO BREAKROOM SINK. |
| |
| 2. PER WPB FBC 107.2.1, PROVIDE APPLICABLE RATED |
| WALL/FLOOR DETAILS FOR PLUMBING PENETRATIONS COMPLYING |
| WITH THE REQUIREMENTS OF FBC CHAPTER 7. |
| |
| 3. PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC PL |
| 704.1, PROVIDE NOTE STATING ?HORIZONTAL DRAINAGE PIPING |
| LESS THAN 3 INCH DIAMETER SHALL HAVE A MINIMUM SLOPE OF |
| 1/4 INCH PER FOOT. 3 INCH TO 6 INCH DIAMETER SHALL HAVE |
| A MINIMUM SLOPE OF 1/8 INCH PER FOOT. |
| |
| 4. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH |
| A NOTE STATING, "HORIZONTAL PIPE SHALL BE SUPPORTED IN |
| ACCORDANCE WITH FBC PL TABLE 308.5." |
| |
| 5. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE |
| LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1. |
| PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS STATING THE |
| SAME. |
| |
| 6. PER FBC PL 606.1(2), PROVIDE A FULL OPEN VALVE |
| BETWEEN THE NEW POINT OF CONNECTION IN THE COMMON AREA |
| AND THE ENTRY POINT INTO THE TENANT SPACE. |
| |
| |
| END OF COMMENTS. |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED |
| AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| |
| |
| |
| JERALD SMITH |
| PLUMBING PLANS EXAMINER PX928 |
| PLUMBING INSPECTOR BN2148 |
| CITY OF WEST PALM BEACH |
| EMAIL [email protected] |
| MOBILE 561-246-0882 |
| PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND |
| THURSDAYS |
| |