Date |
Text |
2022-04-25 13:34:36 | 1ST PLUMBING REVIEW |
| |
| V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE |
| 2021 F.S. - 2021 FLORIDA STATUTES |
| 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE |
| 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE |
| FBC CHAPTER 1 |
| |
| THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED |
| BY RYAN BROWN WITH THE FOLLOWING COMMENTS. |
| |
| 1. SHEET A-5 - BATHROOM NEAR CLUB ROOM - 2020 FRC |
| P3108.1 - THE BAR SINK IN THE CLUB ROOM SHALL DISCHARGE |
| DOWNSTREAM OF THE WET VENT SYSTEM. ONLY BATHROOM GROUP |
| FIXTURES ARE ALLOWED TO DISCHARGE WITHIN THE WET VENT. |
| ALL OTHER FIXTURES MUST DISCHARGE DOWNSTREAM OF THE WET |
| VENT SYSTEM. PLEASE RECONFIGURE AND RESUBMIT. |
| |
| 2. SHEET A-5 - BATHROOM BETWEEN BDRM 2 AND BDRM 3 - |
| 2020 FRC P3108.2.1 - THE TUB AND WATER CLOSET ARE BOTH |
| UPSTREAM OF THE VENTED FIXTURE CONNECTION. NOT MORE |
| THAN ONE WET VENTED FIXTURE DRAIN CAN DISCHARGE |
| UPSTREAM OF THE DRY-VENTED FIXTURE DRAIN CONNECTION. |
| PLEASE RECONFIGURE AND RESUBMIT. |
| |
| 3. SHEET A-5 - MASTER BATH - 2020 FRC P3108.1 - TWO |
| SHOWER TRAPS AND THE WATER CLOSET ARE BOTH UPSTREAM OF |
| THE VENTED FIXTURE CONNECTION. NOT MORE THAN ONE WET |
| VENTED FIXTURE DRAIN CAN DISCHARGE UPSTREAM OF THE |
| DRY-VENTED FIXTURE DRAIN CONNECTION. PLEASE RECONFIGURE |
| AND RESUBMIT. |
| |
| 4. SHEET A-5 - POWDER BATH - 2020 FRC P3108.1 - THE |
| LAUNDRY TUB AND THE AUTOMATIC CLOTHES WASHER ARE |
| DISHCHARGING INTO THE WET VENT FOR THE POWDER BATH. |
| ONLY BATHROOM GROUP FIXTURES ARE ALLOWED TO DISCHARGE |
| WITHIN THE WET VENT. ALL OTHER FIXTURES MUST DISCHARGE |
| DOWNSTREAM OF THE WET VENT SYSTEM. PLEASE RECONFIGURE |
| AND RESUBMIT. |
| |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM. |
| |
| |
| RYAN W. BROWN |
| CHIEF PLUMBING INSPECTOR |
| OFFICE: 561-805-6692 |
| CELL: 561-517-4293 |